____________________________________________________
Blastware Advanced Module
Blastware Operator Manual 6–23
• Range
This section determines the part of an FFT analysis to be printed. You can choose to print
the entire analysis or a section of the analysis.
Print Entire Spectrum – choose this option to print the complete FFT analysis.
Select Frequency (Hz) – this command prints a frequency range of the FFT analysis. Enter
a frequency to start printing in the Start box. Enter a frequency to finish printing in the
End box.
• Frequency Scale
This section determines the frequency scale of the FFT analysis.
Fixed Number Of Pages – this command changes the FFT analysis scale, measured in
hertz, to fit on a specific number of pages.
Hertz Per Page – this command changes the FFT analysis hertz scale to a specific value
you require. Values range from 1 hertz to 500 hertz of Event data per page.
• OK– save the current settings and return to the Print dialog box.
• Cancel – return to the Print dialog box without changing the current settings.
(4) Print Table
This section controls the appearance of tables when printing histogram Events.
i Print Table
Choose this to print a table of the numerical coordinates of the graphical waveform . Click on
the checkbox to display a checkmark.
ii Print All Data
Choose this to have all data appear in the table. Click on the button.
iii Select
Choose this to select which data will appear in the table. Click on the button, then enter the
Start and End time.
(5) Command Buttons
To choose one of the following command buttons, click the mouse pointer on the button.
• Start Printing
Print the advanced Event report.
• Cancel
Return to the Analysis Window without changing the current print settings.
• Save Settings
This command saves the current settings as defaults and will be displayed automatically the next
time you display the Print dialog box.