5-12 Disassembly, Assembly, and Adjustment Rev. A
4. Install {I/F circuit board assembly block] and secure it with the two {CPS-tite (O) M3x6}
screws.
5. While attaching the {main circuit board unit-A} connector to the [I/F circuit board assembly
block] connector with no gap, secure {main circuit board unit-A} with the five {CPS-tite (O)
M3x6} screws.
Level 3 Disassembly and Assembly
I/F circuit board assembly block
CAUTION:
When performing this procedure, be sure to use a grounded wrist band and take other
measures to protect against electrostatic charge.
Circuit board components become hot during normal use. Make sure they are cooled
sufficiently before performing this procedure.
After removing the circuit board, be sure to protect it against electrostatic charge
damage by placing it in an anti-static bag.
1. Remove the two {hexagon screws} ({CPS-tite M3x6} in the case of the parallel interface).
2. Remove {plate-connector-AA} ({plate-connector-BA} in the case of the parallel interface)
from {I/F circuit board assembly}.
Short
Long
Hexagon screw
Serial interface
Plate-
connector-AA
I/F circuit board
assembly
Short
Long
Plate-
connector-BA
CPS-tite M3x6
I/F circuit board
assembly
Comentarios a estos manuales